The recuperator technology is typically a primary surface counterflow design optimized for low pressure losses and high effectiveness at medium pressurisation and high temperatures.
Typical performance data are;
- T max in 650 deg C
- p max 5 bara
- dp cold side 2,5 %
- dp hot side 2,0 %
- effectiveness >89,5 %
The design is made out of high grade stainless steel in a modular fully welded build up.
Durability and life are validated in practical field installations and hot cycle tests.